Equipment Connected Power Rating
3 Bowl Inclined Mangle 7.5 HP (5.5 KW) Up to 1600 mm w.w.
10 HP (7.5 KW) Above 1600 mm w.w.
2/3 Chamber Main Drive 10 HP (7.5 KW)
4/5/6 Chamber Main Drive 15 HP (11 KW)
7/8/9 Chamber Main Drive 20 HP (15 KW)
Blowers 5/10 HP (3.7/7.5 KW) per Chamber
Exhaust ( 5 Chambers) 5 HP (3.7 KW)
Exhaust (More than 5 Chambers) 10 HP (7.5 KW)
Air-Cool Unit 3 HP (2.2 KW)
Motorized Take-up & Plaiter 3 HP (2.2 KW)
Width Variation 3 HP (2.2 KW)
Bow & Weft 0.50 HP (0.36 KW)
Overfeed & Temion 5 HP (3.70 KW)
Uncurlers 0.5 HP (0.4 KW)
Scroll Rolls 2 HP (1.5 KW)
Pinning Device 1.00 HP (0.75 KW)
 
Fuel Consumption Per Chamber
Thermic Fluid 7 to 9 Ltrs/Chamber/Hr.
Gas 5 to 6 Cu. Mt/Chamber/Hour
Coal 15 Kg/Chambe/Hour
Steam 200 Kg/Chamber/Hour
 
Speed Min: 8 M/M, Max: 125 M/M
Water Evaporation Rate 150 Kg/Hr/Chamber under following ideal conditions:
a) Chamber W.W.: 1600 mm or less
b) Chamber Temp: 200°C or more.
Heat Energy Required 1Lac K. Cal/hr/Chamber
(740 K. Cal/Kg of water evaporated)
Jet (Air) Velocity Up to 45 M/Sec.
Jet (Air) CFM 25000 CFM/Chamber
Jet (Air) Pressure 65 mm of water Column
Average Power Consumption 40 to 100 Amp in a std. 5-Chamber Stenter (40 at half blower speeds, 100 at full blower speeds)
Exhaust CFM 3000/Chamber
 
 