1) Type - [a] Single Pass
- [b] Two Pass
- [c] Three Pass
2) No. of Chambers - One to Six
3) Chamber Length - [a] 3 Meters in case of Single Pass
- [b] 1.5 Meters in case of 2-Pass & 3-Pass
4) No. of Hot Air Blowers/ Chamber - Two of 10 HP each
5) No. of Radiators (oil/ Steam)/Chamber - [a] Two in case of Single Pass
- [b] one in case of 2-Pass and 3-Pass
6) Radiator Capacity in terms Of oil content - 80 Ltrs/Radiator
7) Overfeed Up to 40%
8) Shrinkage Control - 8 to 11 %
9) Conveyors - 2 Nos. in Single Pass
- 3 Nos. in Two Pass
- 4 Nos. in Three Pass
10) Conveyor type - PTFE (European).
11) Drives - A.C. Inverters
 
Air Circulation/ nozzle system
» The sinusoidal fabric passage is produced by special nozzles.
»

The air outlet from the nozzle avoids lateral running-off of the fabric. The flow of air is designed so that wide fabric remains wide.

Transport and Restraining Belts(or Conveyors);
» Made from Teflon coated woven fiberglass fabric.
» Temperature Stable
» Simple device for tensioning of the belts.
OverfeedingUnit:
» The fabric is transported with a controlled and reproducible overfeed for optimum relaxing and shrinkage results.
 
 
Home | Photos | Technical Specifications | Features | Dimensions | Customers | Contact Us